- 161KV & a few special high voltage 69KV high-voltage power distribution panel armor
- 3.3~36KV High-voltage power distribution panel lockout
- High voltage integrated boot disk
- Low power plate and control panel
- 600V ACB POWER CENTER Power Center
- MCC Low Voltage Motor Power Center
- PLC program control monitoring system tray
- The low voltage distribution box
- The two-wire control Relay plate
- DC solar disk
Products
TASVC Reactive power compensation device
Scope
Low-voltage reactive power compensation devices are widely used in manufacturing, metallurgy, chemical, electric power, petrochemical, automotive, construction, etc.
Shunt capacitors for induction motor, perceptual load continuous operation of the reactive power compensation. Reduce power transformer and transmission
Line losses, improve power supply efficiency, improve power supply environment.
Deliberate on the basis of regulations and standards
- GB7251(low voltage switchgear).
- GB/T15576(low voltage reactive power compensation device).
- IEC439-1(Low-voltage switchgear and control equipment).
Applicable
- The ambient air temperature is not higher than + 40 ℃, not lower than -5 ℃, and within 24 hours the average temperature is not higher than + 35 ℃.
- The ambient air relative humidity at the highest temperature is 40 ℃ not more than 50%, at a lower temperature allows a greater relative humidity , Such as at + 20 ℃ 90%, but should take into account changes in temperature may occasionally produce moderate condensation.
- Indoor use, place of use of the altitude must not exceed 1000m.
- There should be installed in the absence of severe vibration and shock, and enough to make electrical components should not be corrosion sites.
Characteristic
- TASVC series of low voltage reactive power compensation box by the box, isolating switches, fuses, switched capacitor contactors, Thermal overload relays, power capacitors and intelligent reactive power compensation controller, etc., is a closed box structure.
- Respond promptly, good compensation effect, reliable, can be added to the leakage protection device according to user needs.
- Protection: overvoltage, overload, under voltage, under-current, short circuit and other functions.
- Operating mode: automatic operation and manual operation has two modes of operation an improve power factor above 0.95.
The main technical parameters
Rated voltage 380V Rated frequency 50HZ Compensation Three-phase and single-phase compensation compensation combined Compensation capacity 510kvar~60kvar Reference Size W mm 600 800 1000 D 600 800 1000 H 2200
Product photos